Techmarkets logo
Technical Data for EXFIX

Material Specification
Anchor Body: Polypropylene
Co Polymer
Expansion Pin: Impact Modified,
Glass Filled
Polyamide 6
Application Temperature:
 -30°C to +90°C
The anchor is not suitable for direct long term exposure to UV radiation.  
Anchor
Length



mm
Head
Diameter



mm
Insulation
Thickness



mm
Minimum Embedment
Depth


mm
Drill Diameter



mm
Drilling
Depth into Base Material
mm
 60 50 0 to 30 30 10 50
90 50 30 to 60 30 10 50
110 50 60 to 80 30 10 50
130 50 80 to 100 30 10 50
Ex Fix method illustration

Installation Procedure
  1. Select the correct anchor length according to the guide to suit the thickness of insulation to be fixed.
  2. Drill a 10mm diameter hole through the insulation into the base material. It is recommended that the hole is drilled at least 50mm in to the base material to allow for the expansion pin to clear the end of the fixing.
  3. Insert the anchor body through the insulation and into the pre-drilled hole. Drive the anchor body in using a hammer until the head is level with the surface of the insulation.
  4. Insert the expansion pin into the central hole in the anchor body and drive in with a hammer.
  5. Drive the expansion pin until the head of the pin is level with the head of the anchor. Installation is completed.
Caution: The nail must be driven straight. Hammering at an angle may cause the nail to break.
Loading Performance
Base
Material
Concrete
(25)
Solid
Brick
Concrete
Block
Hollow
Concrete Block
Pull out Load (Given in Kn) 0.80 0.75 0.70 0.45
These loads are ultimate loads. Appropriate safety factors must be applied for design purposes.