Techmarkets logo
Technical Data for IFIX INSULATION FIXING

IFIX is manufactured from Co Polymer Polypropylene.
Application Temperature Range: -30°C to +90°C
The anchor is not suitable for direct, long term exposure to UV radiation.
Anchor
Length



mm
Head
Diameter



mm
Insulation
Thickness



mm
Minimum Embedment
Depth



mm
Drill Diameter



mm
Drilling
Depth into Base Material
mm
 100 90 75 25 10 30
115 90 90 25 10 30
125 90 100 25 10 30
135 90 110 25 10 30
150 90 125 25 10 30
IFIX technical picture



Installation Procedure

 

  1. Select the correct anchor length according to the guide to suit the thickness of insulation to be fixed.
  2. Drill a 10mm diameter hole through the insulation into the base material. It is recommended that the hole is drilled at least 50mm in to the base material.
  3. Insert the IFIX through the insulation in to the pre-drilled hole. Drive the fixing in using a hammer.
  4. Continue hammering in the fixing until the head is level with the surface of the insulation. Installation of the fixing is completed.
Loading Performance
Base
Material
Concrete
(25)
Solid
Brick
Concrete
Block
Hollow
Concrete Block
Pull out Load (Given in Kn) 0.175 0.160 0.150 0.06
These loads are ultimate loads. Appropriate safety factors must be applied for design purposes.

Return to Home Page