Technical Data for IFIX INSULATION FIXING
|
| IFIX is manufactured from Co Polymer Polypropylene. | |
| Application Temperature Range: | -30°C to +90°C |
| The anchor is not suitable for direct, long term exposure to UV radiation. | |
| Anchor Length mm |
Head Diameter mm |
Insulation Thickness mm |
Minimum
Embedment Depth mm |
Drill Diameter mm |
Drilling Depth into Base Material mm |
| 100 | 90 | 75 | 25 | 10 | 30 |
| 115 | 90 | 90 | 25 | 10 | 30 |
| 125 | 90 | 100 | 25 | 10 | 30 |
| 135 | 90 | 110 | 25 | 10 | 30 |
| 150 | 90 | 125 | 25 | 10 | 30 |
![]() ![]() ![]() |
Installation Procedure
|
| Loading Performance | ||||
| Base Material |
Concrete (25) |
Solid Brick |
Concrete Block |
Hollow Concrete Block |
| Pull out Load (Given in Kn) | 0.175 | 0.160 | 0.150 | 0.06 |
| These loads are ultimate loads. Appropriate safety factors must be applied for design purposes. | ||||